SDS2104X Plus Digital Oscilloscope 100MHz
Product Overview
SIGLENT’s SDS2104X Plus, is a 4 Channel 100MHz Digital Storage
Oscilloscope with a maximum sample rate of 2 GSa/s, maximum record length of
200 Mpts/ch and 16 digital channels mixed signal analysis ability. The SDS2104X
Plus employs SIGLENT’s SPO technology with a maximum waveform capture rate of
up to 120,000 wfm/s (normal mode, up to 500,000 wfm/s in Sequence mode),
256-level intensity grading display function plus a color temperature display
mode. It also employs an innovative digital trigger system with high
sensitivity and low jitter. The trigger system supports multiple powerful
triggering modes including serial bus triggering. History waveform recording,
Sequence acquisition, Search and Navigate functions allow for extended waveform
records to be captured, stored, and analyzed. An impressive array of
measurement and math capabilities, options for a 50 MHz waveform generator, as
well as serial decoding, mask test, bode plot, and power analysis are also
features of the SDS2104X Plus. A 10-bit acquisition mode helps to satisfy
applications which require more than 8-bit resolution. The large 10.1’’
capacitive touch screen supports multi-touch gestures, while the remote web
control, mouse and external keyboard support greatly improve the operating
efficiency of the SDS2104X Plus.
Key Features:
with a very small dead time between segments to capture the qualifying event
Options
SDS2000XP-IIS: Decode I2S digital audio signals
SDS2000XP -FlexRay: Analyze Serial Flexray encoded signals
SDS2000XP -1553B: Decode Mil-1553B serial communications
SDS2000XP -CANFD: Analyze CANFD serial signals
SDS2000XP -PA: Power Analysis activation license (Requires external DF2001A deskew fixture)
SDS2000XP -FG: Built-in 50 MHz arbitrary/function waveform generator
Characteristics
Competitive Front End Performance
500 MHz bandwidth (at 2 GSa/s sample rate with 500 MHz bandwidth option).
Up to 120,000 wfm/s waveform update rate
With a waveform update rate of up to 120,000 wfm/s, the oscilloscope can easily capture low-probability events.
In Sequence mode the waveform capture rate can reach 500,000 wfm/s.
Record Length of up to 200 Mpts/ch
Utilizing a hardware-based Zoom technique and record length up to 200 Mpts, users can select a slower timebase
without compromising the sample rate and then quickly zoom in to focus on the area of interest.
10-bit mode Vertical Resolution
10-bit mode combined with Zoom shows you more details and less noise on the waveform.
Multiple Trigger Functions
Edge, Slope, Pulse, Video, Windows, Runt, Interval, Dropout, Pattern and serial trigger.
Trigger Zone
Trigger Zone is available for advanced triggering.
Measurements for All relevant Parameters and Parameter Statistics
Parameter measurements includes 4 categories: horizontal, vertical, miscellaneous and channel delay providing a total of 50+ different types of measurements.
Measurements can be performed within a specified gate period. Measurements on Math, Reference and History frames are supported.
Statistics shows the current value, maximum value, minimum value, standard deviation and mean value of up to 12 parameters simultaneously.
Histogram is available to show the probability distribution of a parameter. Trend is available to show the parameter value vs time.
In addition, horizontal measurements can process up to 1000 signal edges within one single frame, thus greatly improving the test efficiency.
Advanced Math Function
Two Math traces, support FFT, +, -, x, ÷, d/dt, ∫dt, √, average, ERES, and formula editor.
Hardware accelerated FFT up to 2 Mpts. This provides high frequency resolution with fast refresh rate. The FFT function also supports a variety of window
functions so that it can adapt to different spectrum measurement needs. Three modes (Normal, Average and Max hold) can satisfy different requirements for
observing the power spectrum. Auto peak detection and markers are supported.
History Mode
History function records up to 90,000 triggered waveforms (frames). This is done continuously in the background,
so the history waveforms can be played back at any time to find and analyze past events. Serial decode, zoom and
cursors measurements can be used.
Sequence Mode
Segmented memory collection will store the waveform into multiple memory segments (up to 90,000) and each
segment will store a triggered waveform together with the dead time information. The interval between segments
can be as small as 2 µs. All segments can be played back at an arbitrary framerate using the History function.
Search and Navigate
The SDS2000X Plus can find events within a record and history based on user specified trigger conditions.
Navigate browses through Events flagged by the Search, plays back history frames or continuously moves
the delay position on long records (useful in zoom view).
Bode Plot
The SDS2000X Plus can control the built-in waveform generator or any stand-alone SIGLENT SDG device to scan
the amplitude and phase response over frequency of passive or active circuits. The data is presented as Bode Plot.
This makes it possible to replace expensive network analyzers in less demanding applications.
Complete Connectivity
2 x USB Host, 1 x USB Device (USBTMC)
1 x LAN(VXI-11/Telnet/Socket)
1 x Auxiliary Output(Pass/Fail and Trigger Out)
Options
- Upgrade SDS2104X Plus bandwidth to 200MHz
- Built-in 50MHz single channel arbitrary/function waveform generator (Software license)
- Logic probe for SDS2000X Plus series,16-channel, 500MSa/s, 50 Mpts/ch
- MSO function for SDS2000X Plus series (Software license). Logic Probe not included.
- Power Analysis Software for the SDS2000X Plus series (Software license)
- Flexray serial triggering and decoding (Software license)
- MIL-STD-1553B serial triggering and decoding (Software license)
- CAN FD serial triggering and decoding (Software license)
- I2S serial triggering and decoding (Software license)